Listing And Code Approvals; Appliance Certification; Additional Related Standards; Gas Pressure Requirements - Heat & Glo 350TSI-P-CEM Owner's Manual Installation And Operation

Table of Contents

Advertisement

1

Listing and Code Approvals

A. Appliance Certification
MODELS: 350TSI-P-CEM
LABORATORY: BSI
TYPE: Gas Fireplace
STANDARD: Latest version of BS EN613:2001
DIRECTIVE: GAD2009/142/EEC
B. Additional Related Standards
The installation must comply with these installation instruc-
tions and all relevant parts of Local and National Building
Standards Regulations and those relevant recommenda-
tions of the following British Standards. BS 5871: Part 1
BS 8303 BS 5440: Parts 1 & 2 BS 6891 BSEN1856 Parts
1 & 2 BS 5482 Part 1, as well as IGE/UP/7.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
The Heat & Glo gas appliances discussed in this Installer's
Guide have been tested to certification standards and listed
by the applicable laboratories.
Gas Type
Destination
CAT
Qn (Net)
Pn
Pmax
Injector
Efficiency Class
Electrical Requirements: 220-240V / 50 hz / 1A
Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum
inlet pressure of 37 mbar. For pressures over 37 mbar, an in line pressure regulator must be installed
upstream from the gas control valve.
8
G31
ES,FR,GB,GR,LU,NL,SK
II
2H3P
5.4 kw
37 mbar
24 mbar
#55DMS
2
Heat & Glo • 350TSI-P-CEM • 2033-973 Rev. G • 4/17
This appliance must be installed in accordance with the
rules in force.
NOX Class 5 for G20, NOX Class 5 for G31
C. Gas Pressure Requirements
Pressure requirements for 350TSI-P-CEM fireplaces are
shown in table below.
Two taps are provided on the right hand side of the gas
control for a test gauge connection to measure the inlet
and outlet pressures.
The fireplace and its individual shut-off valve must be dis-
connected from the gas supply piping system during any
pressure testing of the system at test pressures in excess
of 60 mbar.
If the fireplace must be isolated from the gas supply pip-
ing system by closing an individual shut-off valve, it must
be of the handle-less type.
WARNING! Risk of Explosion! An in-line regulator
MUST be installed if the gas pressure exceeds 37 mbar.
Failure to install a regulator could damage valve.
G31
NL,NO
II
2H3P
5.4 kw
30 mbar
24 mbar
#55DMS
2
G31
AT,DE,FR,NL,SK
II
2H3P
5.4 kw
50 mbar
24 mbar
#55DMS
2