Uninterruptible power supply
Table of Contents

Advertisement

3
.Operation
Connection capacity/battery level meter
In Commercial Power Mode (normal operation), the connection capacity of devices connected to
the capacity/battery level meter is displayed as a percentage.
BU60RE:
Displayed in 3 levels, with 100% indicating 600 VA/480 W.
BU100RE: Displayed in 3 levels, with 100% indicating 1000 VA/800 W.
When the connection capacity is 30% or less, the level meter turns OFF.
In Battery Mode, the battery level is displayed as a percentage in 3 levels with 100% battery
voltage as fully charged and 0% as discharged.
* In Commercial Power Mode (normal operation), the battery level is displayed when the beeper
stop/test switch is pressed.
(Please note that if the button is pressed and held for 5 seconds or more, the beeper begins to
sound and the self-diagnostic test starts.)
22
In Commercial Power Mode
Connection capacity
Indicator is ON
90% lamp
90% or more
60% lamp
60% or more
30% lamp
30% or more
All OFF
30% or less
Indicator is ON In Battery
Mode Battery remaining
Indicator blinks
60% or more
30 to 60%
0 to 30%