Selecting The Reignition Frequency - Biasi Inovia 25C User Manual And Installation Instructions

Inovia series wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

7.14 Selecting the reignition fre-
quency
When the boiler functions in normal on/off
heating mode, the minimum time between two
ignitions is set at three minutes (re-ignition fre-
quency).
This time can be changed by a minimum of
zero to a maximum of eight and a half minutes
by acting on programming both from the panel
controls and the remote control.
• Enter the "programming mode" by pressing
keys 14 - 17 - 18 (Fig. 7.36) for 10 seconds
at the same time until the letters P01 on the
LCD display, indicating that "parameter 01"
(Fig. 7.37) has been activated.
11
12
13
14 15
Fig. 7.36
Fig. 7.37
• Scroll the various parameters using keys 17
or 18 until the letters P10 are displayed on
the LCD display, indicating that "parameter
10" (Fig. 7.38) has been activated.
- 72 -
COMMISSIONING
Fig. 7.38
• It is possible to modify parameter 10 by
00=0s to 100=510s using keys 11 or 12
(each increase or reduction by a unit on
the display corresponds to 5 seconds). Ex.
36=180 seconds.
• The writing P10 - SEt alternates on the dis-
play (Fig. 7.39).
19
18
17
16
Fig. 7.39
• By pressing key 14 (Fig. 7.36) confirmation
of the inserted value is obtained.
• Press keys 17 or 18 (Fig. 7.36) to exit with-
out changing the value.
• Exiting the "programming mode" is auto-
matic, after 15 minutes, or by cutting power.
Programming using the REMOTE control
Act on the programming of the REMOTE con-
trol to select a minimum time between two ig-
nitions when the boiler functions in normal on/
off heating mode.
• Press button
enter in
for more than 3 seconds to
mode (Fig. 7.40).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Inovia 35cInovia 30c

Table of Contents