mains within the boiler. It is possible for this water to initially cause the pump to seize. It is
therefore recommended that the pump rotor be manually turned to free its rotation before
turning the boiler on.
Remember to release the auto air purge before filling the boiler. See the instructions to
identify the location of this device.
This boiler allows to control the flow temperature of the central heating system at very low
levels. In case of underfloor heating system a temperature limiting device (e.g. a safety
thermostat) is recommended to stop the boiler in case that the water temperature exceeds
the design temperature.
You are strongly advised to flush out the system both cold and hot to the British Standard
BS 7593-2006 Code of practice, in order to remove system and installation debris.
It is also sensible to initially fire and commission the boiler before connecting any external
controls such as a room thermostat. By following this procedure, if you have a subsequent
problem following the addition of an external control, you can eliminate the boiler from your
fault analysis.
If the boiler is fitted with a digital programmer, when setting the times for automatic opera-
tion, remember that for every "ON" time there must be an "OFF" time to follow and that on
every occasion you enter a time you must also indicate which days that you want the boiler
to follow the timed settings.
Some products incorporate an anti cycling time delay. It is normal when first switching the
boiler on for the boiler to operate on heating for a few seconds then switch off. After 3 - 4
minutes has elapsed the boiler will then re ignite and operate perfectly normally. The igni-
tion delay cycle does not prevent normal operation of the boiler to provide d.h.w.
If you are in any doubts as to the installation or operation of the boiler please read the
instruction manuals thoroughly and then if necessary contact Biasi UK for advice and as-
sistance.
Please remember that if you are in any doubt about the installation of this product you can
contact our Technical Help line on tel. 01922 714 600.
Abbreviations used in the manual:
C.h. = Central heating
D.h.w. = Domestic hot water
D.c.w. = Domestic cold wate
Appliance category: II2H3P (gas G20 20 mbar, G31 37 mbar)
Country of destination: United Kingdom (GB) Ireland (IE)
This appliance conforms with the following EEC directive:
Gas Directive 2009/142/CE
Boiler Efficiency Directive 92/42/CEE
Electromagnetic Compatibility Directive 2004/108/CE
Low Voltage Directive 2006/95/CE
The manufacturer, in the continuous process to improve his products, reserves the right to modify the data expressed
in the present documentation at any time and without prior notice.
The present documentation is an informative support and it can not be considered as a contract to-wards third parties.
- 6 -