Biasi Inovia 25C User Manual And Installation Instructions page 76

Inovia series wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

PARAMETER
K
value
(external
probe diagram)
Regulation
of
the
minimum
heating
power
D.h.w. burner turn off
function
NTC on the c.h. re-
turn
User interface
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Minimum heating re-
turn temperature °C
Maintenance
inter-
vals
D.h.w. entry temper-
ature for calculation
def=10
Correct
pressure
main system (Pon)
Fig. 7.49
• Enter the "programming mode" by pressing
keys 14 - 17 - 18 (Fig. 7.50) for 10 seconds
at the same time until the letters P01 are
displayed on the LCD display and the value
of the parameter (35=Inovia 25C, 36=Inovia
30C or 37=Inovia 35C), indicating that "pa-
rameter 01" (Fig. 7.51) has been activated.
- 76 -
COMMISSIONING
DIGIT
VALUES
P 15
P 16
P 17
P 18
P 19
P 20 ---------------
P 21 ---------------
P 22 ---------------
P 23 ---------------
P 24 ---------------
P 25 ---------------
P 26 ---------------
P 27
P 28
P 29
P 30
11
12
13
14 15
Fig. 7.50
Fig. 7.51
• Scroll the various parameters using keys 17
or 18 until the letters P02 are displayed on
the LCD display, indicating that "parameter
02" has been activated.
• Press keys 11 or 12 to change the value and
confirm the value of the parameter with key
14.
• Press keys 17 or 18 (Fig. 7.50) to exit with-
out changing the value.
• Repeat all the above setting sequences in
order to visualize the parameters and their
values.
• Exiting the "programming mode" is auto-
matic, after 15 minutes, or by cutting power.