• Press 10 or 11 (Fig. 8.19) to confirm the
value entered and return to the list of pa-
rameters (Fig. 8.20).
• Press the 15 button (Fig. 8.19) to exit "pro-
gramming mode".
8.6
Setting the pump post-circula-
tion
The pump, in heating function, is set for a
post-circulation of about one minute at the
end of each heat request.
This time can be changed from a minimum
of 10 seconds to a maximum of 20 minutes
in programming mode, using either the con-
trol panel or the remote.
• Enter "programming mode" by pressing
the 15 and 16 keys simultaneously for 5
seconds (Fig. 8.21) until the code P00 ap-
pears on the display, indicating entry into
"parameter P00" (Fig. 8.22).
16
10
11
Fig. 8.21
Fig. 8.22
• Scroll through the various menus by
pressing the keys 10 (back) or 11 (for-
- 54 -
ADVANCED COMMISSIONING
15
14
13
12
RESET
bar
ward), until the LCD display shows the
code P03, indicating entry into "parameter
P03" (Fig. 8.23).
Fig. 8.23
• Press the keys 14, until the value of pa-
rameter P03 on the LCD display (Fig.
8.24).
Fig. 8.24
• It is possible to modify the value of param-
eter 03 from 0 to 99 seconds by pressing
the 13 or 14 keys.
• Press 10 or 11 (Fig. 8.21) to confirm the
value entered and return to the list of pa-
rameters (Fig. 8.23).
• Press the 15 button (Fig. 8.21) to exit "pro-
gramming mode".
8.7
Selecting the reignition fre-
quency
When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set at three minutes (re-igni-
tion frequency).
This time can be changed by a minimum of
0 seconds to a maximum of 255 minutes in
programming mode, using either the control
panel or the remote.