keys 14 - 17 - 18 (Fig. 7.47) for 10 seconds
at the same time until the letters P01 are
displayed on the LCD display, indicating that
"parameter 01" (Fig. 7.46) has been acti-
vated.
Fig. 7.46
11
12
13
14 15
Fig. 7.47
• Scroll the various parameters using keys
17 or 18 until the letters P12 are displayed
on the LCD display and the value of the pa-
rameter (74=Inovia 25C, 78=Inovia 30C or
84=Inovia 35C), indicating that "parameter
12" (Fig. 7.48) has been activated.
Fig. 7.48
• It is possible to modify parameter using keys
11 or 12 (Fig. 7.47) (Refer to Fig. 7.45 and
determine the correct Value appertaining to
the output required for the central heating
COMMISSIONING
requirement.).
• By pressing key 14 (Fig. 7.47) confirmation
of the inserted value is obtained.
• Press keys 17 or 18 (Fig. 7.47) to exit with-
out changing the value.
• Exiting the "programming mode" is auto-
matic, after 15 minutes, or by cutting power.

7.20 Setting record

Important: at the end of the setting opera-
tion it is important to fill/update the table
(Fig. 7.49).
19
This to allow a correct setting of this boiler
in case of replacement of the main control
18
p.c.b.
PARAMETER
17
Boiler type
16
Water sensors con-
figuration
Pump management
TA/OT zone manage-
ment
Gas type
Not used
C.h. flow max tem-
perature °C
Factory
reset
Chimney
function
C.h. reignition fre-
quency
C.h. pump post-circu-
lation
Max. useful output in
c.h. mode
C.h. pump working
type
Ignition power
DIGIT
P 01
P 02
P 03
P 04
P 05
P 06 ---------------
P 07
parameters
P 08
sweep
P 09
P 10
P 11
P 12
P 13
P 14
VALUES
- 75 -