Setting The Pump Post-Circulation - Biasi Inovia 25C User Manual And Installation Instructions

Inovia series wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

eter, indicating entry in "parameter 03" (Fig.
7.26).
Fig. 7.26
• Use key 11 or 12 to modify the value of
parameter 03 to 00=maximum speed or
01=average speed.
• The writing P03 - SEt alternates on the dis-
play (Fig. 7.27).
Fig. 7.27
• By pressing key 14 (Fig. 7.24) confirmation
of the inserted value is obtained.
• Press keys 17 or 18 to exit without changing
the value.
• Exiting the "programming mode" is auto-
matic, after 15 minutes, or by cutting power.
7.13 Setting the pump post-circula-
tion
The pump, in heating function, is set for a
post-circulation of about one minute at the end
of each heat request.
This time can be changed by a minimum of
zero to a maximum of four minutes by acting
on programming both from the panel controls
- 70 -
COMMISSIONING
and the remote control.
• Enter in "programming mode" by pressing
keys 14 - 17 - 18 (Fig. 7.28) for 10 seconds
at the same time until the letters P01 are
displayed on the LCD display, indicating that
"parameter 01" (Fig. 7.29) has been acti-
vated.
11
12
13
Fig. 7.28
Fig. 7.29
• Scroll the various parameters using keys 17
or 18 until the letters P11 are displayed on
the LCD display, indicating that "parameter
11" (Fig. 7.30) has been activated.
Fig. 7.30
• It is possible to modify parameter 11 by
00=0s to 99=255s using keys 17 or 18
(each increase or reduction by a unit on the
14 15
19
18
17
16