7.13 Selecting the reignition fre-
quency
When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set at three minutes (re-igni-
tion frequency).
This time can be changed by a minimum of
zero to a maximum of eight and a half min-
utes by acting on programming both from
the panel controls and the remote control.
• Enter the "programming mode" by press-
ing keys 14 - 15 - 16 (Fig. 7.35) for 10
seconds at the same time until the let-
ters Pr that alternate with code 01 are
displayed on the LCD display, indicating
that "parameter 01" (Fig. 7.36) has been
activated.
12
13
Fig. 7.35
Fig. 7.36
• Scroll the various parameters using keys
15 or 16 until the letters Pr that alternate
- 68 -
COMMISSIONING
16
15
14
with code 10 are displayed on the LCD
display, indicating that "parameter 10"
(Fig. 7.37) has been activated.
Fig. 7.37
• Press keys 14 and 16 (Fig. 7.35) at the
same time until the value of parameter
10 (30=180 seconds) is displayed on the
LCD display (Fig. 7.38).
Fig. 7.38
• It is possible to modify parameter 10
by 00=0s to 99=600s using keys 15 or
16(each increase or reduction by a unit on
the display corresponds to 6 seconds).
• By pressing key 14 (Fig. 7.35) confirma-
tion of the inserted value is obtained.
• Press keys 14 and 15 (Fig. 7.35) at the
same time to exit without changing the
value (return to the parameters list Fig.
7.37).
• Press keys 14 - 15 - 16 (Fig. 7.35) at the
same time for 10 seconds to exit the "pro-
gramming mode".
Programming using the REMOTE control
Act on the programming of the REMOTE