Note
The mini-touch panel must
always be installed with the
release slot located at the
bottom.
Figure 10
AXM-MLC rack-mount mini-
touch panel
Black/White LCD Mini-Touch Panels
Remove the BB-MTP and drill four #6-32 insert holes. Then, place a threaded
5.
insert into each hole.
Disconnect the AXlink connector from the AMX control system that supplies
6.
power and data to the AXU-MLC (/PB). Then, disconnect the optional RS-232
connector from the external RS-232 device connected to the AXU-MLC (/PB).
Thread the incoming AXlink and RS-232 wiring through the BB-MTP knockout.
7.
Fasten the BB-MTP to the plasterboard using the expansion screws supplied
8.
with the enclosure.
Connect the AXlink and RS-232 wiring to the AXU-MLC (/PB) circuit card.
9.
Refer to Wiring the Mini-Touch Panels for complete wiring information.
Fasten the AXU-MLC (/PB) to the BB-MTP with the #6-32 screws supplied with
10.
the enclosure.
Insert the engraved overlay back into the bezel.
11.
Connect the AXlink wiring to the AMX control system and RS-232 wiring to the
12.
external RS-232 device. The AXU-MLC (/PB) will beep when you apply power.

AXM-MLC (rack mount)

Mount the AXM-MLC ( Figure 10) rack mount into an electronic equipment rack:
Thread the incoming AXlink and RS-232 (optional) wiring through the opening
1.
in the equipment rack.
Disconnect the AXlink connector from the AMX control system that supplies
2.
power and data to the AXM-MLC. Then, disconnect the optional RS-232
connector from the external RS-232 device connected to the AXU-MLC (/PB).
Installing the Mini-Touch Panel
11