Set Serial - AMX LCD Mini-Touch Panels Instruction Manual

Black/white lcd mini-touch panels
Table of Contents

Advertisement

Figure 93
Adjust Serial Settings page
Note
You can still control the mini-
touch panel with your finger
when mouse control is active.
Note
Make sure to match the baud
transmission rate for the
external RS-232 device.
62
Mini-Touch Panel Program Reference

Set serial

Press the SET SERIAL button to open the Adjust Serial Settings page shown in
Figure 93.
ADJUST SERIAL SETTINGS
SPEED
MICROSOFT
8
MOUSE
UP
DN
BAUD
BOTH
38.4
MODE
UP
DN
The 4-pin header in the UniMount and rack-mount mini-touch panels are set to 1,200
baud when you activate the MOUSE ON button. The RS-232 communication
automatically defaults to the baud rate set on the Set Serial page if you disable the
MOUSE ON button.
• SPEED
Increases or decreases the movement speed of the mouse pointer
with the up and down arrows. Minimum (slow) speed is 1 and the maximum
(fast) is 10.
• BAUD
Press the up or down arrow to set the data communication speed for
the mini-touch panel' s RS-232 port. The baud rates are 300; 600; 1,200; 2,400;
4,800; 9,600; 19,200; and 38,400.
• MICROSOFT MOUSE or LOGITECH MOUSE
interface for a Microsoft or Logitech mouse.
• BUS MODE, RS232 MODE, BOTH MODE
the mini-touch panel.
BUS MODE
Transmits AXlink data through the AXlink connector on the
mini-touch panel.
EXIT
MOUSE
ON
POWER UP
MESSAGE
Sets the data signal output for
Sets the mouse control