Message
System under recommended CPU x
temperature (level-warning; system
reporting under temperature condition for
CPU x)
Fan error messages
Message
Fan x failure (level-critical; fan x had a
failure)
Fan x fault (level-critical; fan x beyond
recommended RPM range)
Fan x outside recommended speed
action
Power error messages
Message
Power Supply x current share fault
(level-critical excessive current demand on
power supply x)
Power supply x DC good fault
(level-critical; power good signal not detected
for power supply x)
Power supply x temperature fault
Power supply x removed
Power supply x fan fault (level-critical; fan
fault in power supply x)
Power supply x 12 V fault (level-critical;
overcurrent condition detected)
Power supply x 3.3 V fault (level-critical;
3.3 V power supply x had an error)
Power supply x 5 V fault (level-critical; 5 V
power supply x had an error)
System running non-redundant power
(level-noncritical; system does not have
redundant power)
System under recommended voltage for x
(level-warning; indicated voltage supply
under nominal value; value for x can be +12,
-12, or +5)
Action
Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 3.
Action
1. Check connections to fan x.
2. Replace fan x.
1. Check connections to fan x.
2. Replace fan x.
Replace fan x.
Action
Replace power supply x.
Replace power supply x.
Replace power supply x.
No action required - information only.
Replace power supply x.
See "Power checkout" on page 25.
See "Power checkout" on page 25.
See "Power checkout" on page 25.
1. Add another power supply.
2. Remove options from the computer.
3. The computer can continue to operate without redundancy
protection if steps1 and 2 are not followed.
1. Check connections to the power subsystem.
2. Power supply.
Chapter 6. Symptom-to-FRU index