POST error codes

In the following error codes, X can be any number or letter.
Error code/symptom
062
(Three consecutive boot failures using the
default configuration.)
101, 102, 106
(System and processor error)
151
(Real time clock error)
161
(Real time clock battery error)
162
(Device configuration error)
Note: Be sure to load the default settings
and any additional desired settings; then,
save the configuration.
163
(Real-time clock error)
164
(Memory configuration changed.)
184
(Power-on password damaged)
187
(VPD serial number not set.)
189
(An attempt made to enter the system with
invalid passwords)
201
(Memory test error.)
289
(DIMM disabled by the user or system.)
301
(Keyboard or keyboard controller error)
303
(Keyboard controller error)
FRU/action
1. Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
4. Microprocessor.
System board
1. Run diagnostics.
2. Battery.
3. System board.
1. Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
1. Run the Configuration/Setup Utility program.
2. Battery.
3. Failing device.
4. System board.
1. Run the Configuration/Setup Utility program.
2. Battery.
3. System board.
1. Run the Configuration/Setup Utility program.
2. DIMM.
3. System board.
1. Run the Configuration/Setup Utility program.
2. System board.
1. Set serial number in the Configuration/Setup Utility program.
2. System board.
Run the Configuration/Setup Utility program.
1. DIMM
2. System board
1. Run the Configuration/Setup Utility program.
2. DIMM.
3. System board.
1.
Keyboard
2. System board
System board