Hard disk drives / solid state drives
6.2.5
Concluding steps
Perform the following procedures:
"Closing the rack door" on page 65
Ê
Ê If applicable, please observe the notes on RAID rebuild in section
"Performing a RAID array rebuild" on page 97
6.3
Removing a 2.5-inch HDD/SSD module
Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
Only applicable for removing non-defective HDD/SSD modules:
Ê Set the drive to "Offline" via the software (RAID controller
configuration software), before removing an HDD/SSD module that is
not defective.
6.3.1
Required tools
Preliminary and concluding steps: tool-less
●
Main steps: tool-less
●
6.3.2
Preliminary steps
Perform the following procedures:
Ê Only applicable for removing intact HDD/SSD modules (for example:
preventive exchange in case of S.M.A.R.T):
Ensure that the HDD/SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete the
array using ServerView RAID Manager.
108
Upgrade and Maintenance Manual
BX920 S3