Calibrate Sensor By Running A Distance (On-The-Fly Calibration); Set Calibration Factor Manually - Polar Electro RS800CX User Manual

Hide thumbs Also See for RS800CX:
Table of Contents

Advertisement

recommended that you calibrate the sensor before using it for the first time, if there are significant
changes in your running style, or if the position of the sensor on the shoe is dramatically changed (e.g. if
you have new running shoes). You can calibrate the sensor by running a known distance, or by setting the
calibration factor manually.
You can calibrate one s3 sensor for each shoe setting.

Calibrate Sensor by Running a Distance (on-the-fly calibration)

You can calibrate the sensor at any phase of your exercise with lap distance correction, provided you are
not exercising with distance-based targets. Just run a known distance, preferably more than 1000 meters.
Make sure the sensor function in the training computer is on (
).
1/2/3 > On
In time mode press OK once. Select
Then select
and start running.
Start
When you are in a starting point of a known lap distance, press OK. When you have run the whole lap
distance, press OK. Then calibrate the sensor by choosing either alternative:
1.
Press and hold LIGHT to go to
2.
Press STOP once. Select
Select
Calibrate > Correct lap > Set true lap distance
you just ran, and press OK.
and the factor are displayed. The sensor is now calibrated and ready for action.
Calibration complete

Set Calibration Factor Manually

The calibration factor is calculated as a ratio of the actual distance to the uncalibrated distance. Example:
you run 1200m, the training computer shows a distance of 1180m, the calibration factor is 1.000.
Calculate the new calibration factor as follows: 1.000*1200/1180 = 1.017. The measuring range for the
factor is 0.500-1.500.
There are four options for setting the calibration factor:
1.
Before exercise.
Select
Settings > Features > Shoes/bikes > Shoe 1/2/3 > Calibrate
Set the
Calibration factor
2.
During exercise by pausing exercise recording.
Start exercising by pressing OK twice in the time display. Press STOP once and the exercise recording is
paused.
Select
Settings > Calibrate > Set factor
Set the
Calibration factor
pressing OK.
3.
During exercise without pausing exercise recording.
Start exercising by pressing OK twice in the time display. Press and hold LIGHT to get to
Select
Calibrate > Set factor
Set the
Calibration factor
Settings > Shoes/bikes > Shoes 1/2/3
Settings
. Or,
.
Settings
and press OK. The sensor is now calibrated.
.
and press OK. The sensor is now calibrated. Continue exercise recording by
.
and press OK. The sensor is now calibrated. Continue running.
Settings > Features > Shoes/bikes > Shoes
.
. Fix the displayed lap distance with the distance
.
Prepare For Training
ENGLISH
.
Settings
11

Advertisement

Table of Contents
loading

Table of Contents