6
Disassembly / Reassembly
1
2
4
- 38 -
3
KD 702_1003_1404 Workshop Manual_cod. ED0053029340_1° ed_ rev. 00

Dry type air filter

Danger - Attention
Never clean the filtering element with highly flammable sol-
vents Danger of explosion!
Important
Blow compressed air crossways over the external part and
inside the cartridge at a pressure no greater than 5 atm
or if necessary knock the front of the cartridge repeatedly
against a flat surface.
Components: 1 Cover
2 Filter element
3 Support
Air filter specifications:
Filtration level
= 13÷14 µm.
Filtration area
= 4470 cm²
Filtration area
= 7150 cm²
See page 32 for periodic maintenance details.

Air restriction switch

Components:
1 Reset buttione
2 .25" Tab connection
Note: The indicator is calibrated at 600÷650 mm of water co-
lumn for KDW 702, 1003, 1404.

Oil bath air cleaner (on request)

Important
Check the sealing rings regularly.
Replace the sealing rings if hardening or damage is noted
1 Upper Housing
2 Diaphragm Seat
3 Diaphragm
4 Polyurethane upper element
5 Metal wool lower eleme
Note: Carefully clean the reservoir bowl and both elements with
clean diesel fuel. Blow the lower element dry with com-
pressed air. Dry the upper element by squeezing out ex-
cess diesel fuel, then drying with suitable cloths.
Fill the reservoir with clean engine oil to the reference
mark.
See page 32 for periodic maintenance and replacement
details.
for 702, 1003
for 1404
6 Oil level reference mark
7 Reservoir bowl
8 Outer seal ring
9 Inner seal ring

Advertisement