Pump/Injector Unit Delivery Setting With Braked Engine - Kohler KDW 702 Workshop Manual

Water-cooled, indirect injection
Hide thumbs Also See for KDW 702:
Table of Contents

Advertisement

12
Settings
224
- 106 -

Pump/injector unit delivery setting with braked engine

1) Run the engine to the maximum speed.
2) Screw flow limiter C (see fig. 219).
3) Load the engine up to the power and number of revs required
by the application's manufacturer.
4) Check that consumption is within the values allowed for in the
settings table (see below).
If consumption is not within the given figures, it is necessary
to change the balance conditions shown to the brake, alte-
ring the load and the speed governor. Redo the consumption
check on the stabilised engine.
5) Unscrew limiter C until the engine rpm start to decrease. Lock
the limiter using the lock nut.
6) Completely release the brake and check the rpm at which the
engine stabilises.
The performance of the speed governor must meet the class
required by the application's manufacturer.
7) Stop the engine.
8) Recheck the valve clearance with the engine cold.
KD 702_1003_1404 Workshop Manual_cod. ED0053029340_1° ed_ rev. 00