Printing Supplies Replacement; Toner Cartridge Replacement - Toshiba ESTUDIO170F Operation Manual

Plain paper facsimile
Hide thumbs Also See for ESTUDIO170F:
Table of Contents

Advertisement

- PRINTING SUPPLIES REPLACEMENT

Toner Cartridge Replacement

Replacement Toner Kits for your TOSHIBA facsimile include a
Toner Cartridge.
Your TOSHIBA facsimile has been designed to display a two
stage alert to replace Toner once it has been depleted.
The first stage is a "TONER LOW" warning that alerts you that the
Toner is low and should be replaced at your earliest convenience.
The unit will continue to receive and print facsimile messages dur-
ing this stage.
The second stage is a "TONER EMPTY" notice. When this mes-
sage is displayed, the machine can no longer print documents.
Receptions will be stored in memory until the Toner has been re-
placed.
It is recommended to replace the Toner Cartridge whenever the
"TONER LOW" message is displayed using the following proce-
dure.
IMPORTANT:
When you use a toner cartridge of our recommendation, the fac-
simile machine can detect whether or not the cartridge is inserted
in the machine and alert the user when the amount of toner is low
or needs replacing. As the facsimile machine does not start print-
ing when the toner is not inserted or when the amount of toner is
insufficient, loss of received data can be prevented. If a toner car-
tridge other than that of our recommendation is used, the machine
may not be able to detect whether the toner cartridge has been
inserted or if the toner amount is sufficient, and printing is not pos-
sible using the default setting.
If you want to use a toner cartridge other than that of our recom-
mendation, please inform our service center. The service center
will change the machine setting to cancel the detection function.
Please note, however, that when the setting is so changed, the
machine will start printing even if a toner cartridge is not inserted
or the toner amount is insufficient. Consequently, the printout may
not be satisfactory and the received data may be lost.
1
Open the Front
Cover
Hold the Front Cover by the
grips on both sides of its upper
part and pull it down to open it.
NOTE:
Do not pull the Front Cover
too strongly when opening
it.
2
Remove the Process
Unit
Lift up and holding the green
handle, gently pull out the Pro-
cess Unit.
CAUTION:
Always hold the Process
Unit by the green handle.
Detach the Toner
3
Cartridge from the
Drum Unit
Move the lever of the Toner
Cartridge in the direction of the
arrow to detach it from the
Drum Unit.
NOTES:
• Keep the Toner Cartridge
level with the Drum Unit
when they are detached.
• Do not touch the PC Drum
under the lid of the Drum
Unit. The image quality
could be degraded.
• Do not touch the metal area
of the Toner Cartridge. It
could be damaged due to
electrostatic interference.
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio 170f

Table of Contents