Sampling Procedure - Roland V-Synth XT Owner's Manual

Hide thumbs Also See for V-Synth XT:
Table of Contents

Advertisement

Setup
Comp
Limiter
SamplingType 0 (Stereo)
0 (Stereo)
InputSource
0 (Analog)
0 (Analog)
TriggerMode
0 (Manual) 0 (Manual) 1 (MIDI)
TriggerLevel
-12 (dB)
-12 (dB)
PreTrigger
0 (0msec)
0 (0msec)
PreGain
0 (0dB)
0 (0dB)
PreFxType
1 (COMP)
2 (LIMIT)
PreFxCS-Sus
64
0
PreFxCS-Atk
12
0
PreFxCS-Tone
0
0
PreFxCS-Lvl
0
0
PreFxLM-Thr
-48
-36
PreFxLM-Rel
0
80
PreFxLM-Rati
0
2
PreFxLM-Tone 0
0
PreFxLM-Lvl
0
0
PreFxNS-Thr
-60
-60
PreFxNS-Rel
0
0
CountIN
1 (1MES)
1 (1MES)
MetroType
1 (REC)
1 (REC)

Sampling Procedure

Here's how to input a sound from the input jacks and sample it. For
resampling, refer to the following section.
The V-Synth XT has the following input jacks.
• INPUT L, R
• MIC
• DIGITAL AUDIO INTERFACE
OPTICAL IN
COAXIAL IN
• USB
Use the input jack that is appropriate for your situation.
• Monaural sampling from a mic → MIC
• Sampling from an analog source → INPUT L, R
• Sampling from a digital source → OPTICAL IN or COAXIAL IN
• Sampling from a PC USB Audio → USB
The on/off status of the MIC jack and INPUT jacks and the gain
setting for the INPUT JACKS are adjusted using the System
parameter "Audio I/F" (p. 126).
The impedance type selection and phantom power supply for
the MIC jack are specified by "MIC Switch" (p. 14).
Creating and Editing Samples (Sample Mode)
MIDI
USB (XT)
0 (Stereo)
0 (Stereo)
0 (Analog)
4 (USB)
2 (Level)
-12 (dB)
-24 (dB)
0 (0msec)
0 (0msec)
0 (0dB)
0 (0dB)
0 (off)
0 (off)
0
0
0
0
0
0
0
0
-48
-48
0
0
0
0
0
0
0
0
-60
-60
0
0
0 (0MES)
0 (0MES)
1 (REC)
1 (REC)
Howling could be produced depending on the location of
microphones relative to speakers. This can be remedied by:
1. Changing the orientation of the microphone(s).
2. Relocating microphone(s) at a greater distance from speakers.
3. Lowering volume levels.
When sampling, you must make sure that the following two items
are set correctly. If these two settings are incorrect, the sample will
not be recorded as you intend.
• What type of sample are you recording? (stereo or mono)
→ In the SAMPLING General screen, set Sampling Type.
• Which input are you sampling from? (select the input jack)
→ In the SAMPLING General screen, set Input Source.
If you have set the metronome (p. 111), the metronome sound
will be output from the DIRECT OUT jack during sampling.
However, the sound that is assigned to the DIRECT OUT jack (p.
97) will not be output.
1. Press [MODE].
The V-SYNTH XT MODE MENU window appears.
fig.MODE_50
2. Touch <SAMPLE>.
The SAMPLE Top screen appears.
fig.04-01_50
983
105

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents