Hot-Plug Operation Procedures; Slot Id Numbering - HP Integrity rx4640 Service Manual

Hide thumbs Also See for Integrity rx4640:
Table of Contents

Advertisement

1
The conditions described in this table apply only to shared slots (slots 3,4-bus 2 and 5,6-bus 3). Slots 7 and 8 are not
shared slots.
2
Compatible: card is accepted and runs at frequency shown.
3
Incompatible-Frequency: card is rejected. The new card will not initialized and powers off due to frequency mismatch.
4
Incompatible-Bus: Card is rejected. The new card will not initialize and powers off due to bus mode mismatch.
5
Maximum bus mode and frequency supported on shared slots is PCI-X 66 MHz.
CAUTION:
If you are using the Linux Red Hat Enterprise Advanced Server 4 Update 3 operating
system and you want to install a 1000b-Sx GigE card, do not install it into a slot that shares a bus
with a 33 MHz card. In this configuration the Linux driver will not initialize the new card.
CAUTION:
limitations restrict the use of more than 3 RAID cards per server.
Figure 4-25 Slot ID Numbering

Hot-Plug Operation Procedures

The hot-plug procedures described in this section use the hardware interface only. Software
interface procedures are described in
and OS
Availability". For a complete understanding of all HP-UX 11i v2 hot-plug techniques
64
Removing and Replacing Components
Do not use more than 3 RAID cards in any of the slots on the server. Server power
Table 4-7: "Hot-Plug Hardware and Software Interfaces