Online Replacement (Ol-R); Removing And Replacing Olx Dividers - HP Integrity rx4640 Service Manual

Hide thumbs Also See for Integrity rx4640:
Table of Contents

Advertisement

9.
Push the server all the way back into the rack until it stops. See
the Rack" (page

Online Replacement (OL-R)

As discussed earlier, OL-R is a combination of an OL-D procedure followed by an OL-A procedure.
CAUTION:
To remove and replace a PCI-X card into a populated slot, follow these steps:
1.
If rack mounted, slide the HP server out from the rack until it stops. See
Server From the Rack" (page
2.
Remove the top cover from the chassis. See
3.
Press the attention button located on the OLX divider that controls the affected slot. The
power LED starts to blink. Wait until the power LED goes from blinking to steady-off.
NOTE:
by pushing the attention button again.
4.
Turn the PCI-X card lock on the chassis until the manual retention latch (MRL) is free to
pull up.
5.
At this point, the power to the slot is off; pull up on the manual retention latch located on
the OLX divider.
6.
Remove the existing PCI-X card from the slot.
7.
Insert the new PCI-X card into the powered off slot.
install a PCI-X card.
CAUTION:
attention button on the other OLX dividers. This initiates an undesired shutdown of another
PCI-X card/slot. If you accidentally press the wrong attention button, you have five seconds
to push the attention button again to cancel the action.
Also, ensure that you fully seat the card into the slot or undesired results may occur after
power is reapplied to the slot.
8.
Push the manual retention latch down until it seats against the chassis wall.
9.
Turn the PCI-X card lock on the chassis to the closed position. This locks the PCI-X card into
its slot and the manual retention latch into the closed position.
10. Press the attention button. The power LED starts to blink.
11. Wait for the power LED to stop blinking. The PCI-X card is now active.
12. Replace the top cover.
13. Push the HP server all the way back into the rack until it stops. See
into the Rack" (page

Removing and Replacing OLX Dividers

OLX dividers are located on the I/O baseboard, between the PCI cards. Six OLX dividers provide
short circuit protection to the hot-plug PCI accessory boards by preventing inadvertent contact
between boards during the replacement or addition of a board.
68
Removing and Replacing Components
32).
For HP-UX 11i v2 only. You can only replace an existing card with a like card.
31).
After pushing the attention button, you have five seconds to cancel the operation
Figure 4-26
shows the layout of the PCI-X card divider.
When inserting the PCI-X card, be careful you do not accidentally touch an
"Replacing the Top Cover" (page
32).
"Inserting the Server into
"Removing the Top Cover" (page
Figure 4-27
shows how to correctly
36).
"Extending the
36).
"Inserting the Server