Frequency And Synchronization; Intrinsic Uncertainty (Reference Conditions) - Fluke NORMA 4000 Operator's Manual

Power analyzer
Hide thumbs Also See for NORMA 4000:
Table of Contents

Advertisement

Frequency and Synchronization

Range
Measurement error
Channel selection
Low-pass filter
External Sync-input
Sync-output

Intrinsic Uncertainty (Reference Conditions)

Sample Rate
Bandwidth
45 to 65 Hz
10 to 1000 Hz
% of reading +
% of range
10 kHz
100 kHz
45 to 65 Hz
Angular error
(degrees)
10 to 1000 Hz
45 to 65 Hz
% of reading +
10 to 1000 Hz
% of range
10 kHz
100 kHz
45 to 65 Hz
Angular error
(degrees)
10 to 1000 Hz
0.2 Hz to Sample rate (102 kHz / 341 kHz / 1 MHz)
±0.01 % rdg
all channels U/I, or external input
optionally integratable, with 3 different limit frequencies
Maximum 50 V, 0,2 Hz to sample rate
Pulsed TTL signal 5 V
PP42
PP50
341 kHz
1024 kHz
3 MHz
10 MHz
0.1 + 0.1
0.05 + 0.05
0.1 + 0.1
0.05 + 0.05
0.25 + 0.25
0.2 + 0.2
0.5 + 0.5
0.4 + 0.4
0.005
0.005
0.005 +
0.005 +
0.005/kHz
0.005/kHz
0.1 + 0.1
0.05 + 0.05
0.1 + 0.1
0.05 + 0.05
0.25 + 0.25
0.2 + 0.2
0.5 + 0.5
0.4 + 0.4
0.005
0.005
0.005 +
0.005 +
0.015/kHz
0.010/kHz
Technical Data Fluke NORMA 4000/5000
PP52
PP54
341 kHz
341 kHz
3 MHz
3 MHz
0.05 + 0.05
0.05 + 0.05
0.05 + 0.05
0.05 + 0.05
0.2 + 0.2
0.2 + 0.2
0.4 + 0.4
0.4 + 0.4
0.005
0.005
0.005 +
0.005 +
0.005/kHz
0.005/kHz
0.05 + 0.05
0.05 + 0.05
0.05 + 0.05
0.05 + 0.05
0.2 + 0.2
0.2 + 0.2
0.4 + 0.4
0.4 + 0.4
0.005
0.005
0.005 +
0.005 +
0.010/kHz
0.005/kHz
11
Technical Data
PP64
341 kHz
3 MHz
0.01 + 0.02
0.03 + 0.02
0.2 + 0.2
0.4 + 0.4
0.002
0.005 +
0.005/kHz
0.01 + 0.02
0.03 + 0.02
0.2 + 0.2
0.4 + 0.4
0.0025
0.005 +
0.005/kHz
11-5