Functions

The Power Analyzer allows for the analysis of currents from dc to several MHz. Voltage
values up to 1000 V and currents up to 20 A (depending on measurement modules
installed in the instrument) are measured accurately, and the respective real, reactive, and
apparent power is calculated. The limit of error is between 0.03 % and 0.3 %, depending
on the model. See the technical specifications for detailed information. For dc and ac up
to a few MHz, it is not affected by the wave shape, frequency, or phase position. The
measuring range can be extended by connecting shunts or clamps. When extending the
range using third-party shunts or clamp, the extra errors due to these devices should be
considered. The device allows for simultaneous measuring in up to six channels.
Design and Functions