Nortel 1000 Applications Installation And Commissioning page 130

Linux platform base
Table of Contents

Advertisement

130 COTS Servers
5
6
7
Setting the HP DL320 G4 server BIOS password
Step
1
Figure 119
HP DL320 G4 server boot screen
2
Linux Platform Base and Applications Installation and Commissioning
Copyright © 2007–2008 Nortel Networks
.
A BIOS Serial Console Baud Rate configuration window
appears. This window presents you with four settings for the
serial port speed:
9600
19200
57600
115200
Navigate to the 9600 setting and press Enter.
This configures the serial port speed to 9600 b/ps.
The BIOS Serial Console & EMS configuration menu screen
reappears.
Press ESC to exit the BIOS Serial Console & EMS configuration
menu screen.
The RBSU menu screen reappears.
Press ESC to exit the ROM-based Setup Utility.
Action
Press Power to boot the server.
The server boots and the HP DL320 G4 boot screen appears.
Note: If the server is already up and running, power the
server off and on to reboot and receive the HP DL320 G4
boot screen.
Press F9 to invoke the ROM-based setup utility (RBSU) menu
screen.
The RBSU menu screen appears.
Nortel Communication Server 1000
NN43001-315 02.09
29 October 2008
--End--