[Cnt Ac-J Z] Clear-Sim; [Cnt Ac-J Z] Delete-Pair - HP StorageWorks P9000 - Disk Arrays Reference Manual

Hp storageworks p9000 audit log user and reference guide (av400-96333, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Detailed Information
Item
LDKC
JNL
MirrorID
Copy Pace
Path Blockade
Watch(m)
Forward Path
Blockade Watch
Transfer Speed(Mbps)
Delta resync Failure
Result
Num. of Mirrors

[Cnt Ac-J Z] Clear-SIM

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-J Z],Clear-SIM,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx

[Cnt Ac-J Z] Delete-Pair

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[Cnt Ac-J Z],Delete-Pair,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{P-VOL(LDKC:CU:LDEV),S-VOL(LDKC:CU:LDEV),MirrorID,
S/N,CTRLID,Type,Range,Delete Mode,Result}
=[{0x00:0x00:0x00,0x00:0x20:0x00,0x00,0x00,65432,5,
P-VOL,Volume,Normal,Normal end},(snip)
-{0x00:0x00:0x02,0x00:0x20:0x02,0x00,0x00,65432,5,P-VOL,Volume,
Normal,Normal end},Num.of Pairs=3
Detailed Information
Item
P-VOL(LDKC:CU:LDEV)
S-VOL(LDKC:CU:LDEV)
Description
The LDKC number where the journal belongs.
The journal number.
The mirror ID.
The speed of initial copy. 150: Low speed, 500: Medium speed, 1500: High speed
The path blockade watch period set. The units are minutes, hours or days. If it is set to 30
minutes, it will be 30 (min.).
Indicates whether to transfer the path blockade watch period of the master journal to the restore
journal.
Yes: Transfer, No: Do Not Transfer.
The transfer speed of the communication line. The unit is megabits per second (Mbps).
Indicates the operation mode when Delta resync operation have failed.
Entire: Copy the entire data volume, None: Do not copy the data volume
The result of operation.
Normal end: Normal end, Error(xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of mirrors.
Description
The LDKC, CU, and LDEV numbers of the primary data volume.
If the LDKC:CU:LDEV is set using a spreadsheet and the Type is S-VOL, N/A will be
output for both CU and LDEV numbers.
The LDKC, CU, and LDEV numbers of the secondary data volume.
If the LDKC:CU:LDEV is set using a spreadsheet and the Type is P-VOL, N/A will be
output for both CU and LDEV numbers.
Continuous Access Journal Z Descriptions
167

Advertisement

Table of Contents
loading