Parallel Wrap Test - Lexmark Optra C710 Service Manual

Service manual
Hide thumbs Also See for Optra C710:
Table of Contents

Advertisement

5016-001

Parallel Wrap Test

This test is used with a wrap plug to check operation of the parallel
port hardware. Each parallel signal is tested.
To run the Parallel Wrap Test:
1. Disconnect the parallel interface cable and install the wrap plug
(P/N 1319128).
2. Select the Parallel Wrap Test from the menu.The power
indicator blinks indicating the test is in progress. The test runs
continuously until canceled.
When the test finishes, the screen updates. If the test passes, the
Pass Count increases by 1, however if the test fails, one of the
following messages display for approximately 3 seconds:
Sync Busy Error
Strobe Interrupt Request Error Init Fail Error
Init Busy Error
Host Busy Error
RAM Data AA Error
RAM Data 55 Error
DMA Address Error
DMA Memory Error
Clear Init Rise Error
Autofeed Rising Interrupt Error Clear Autofeed Rise Error
False Autofeed Rise Error
Clear Autofeed Fall Error
Once the maximum count is reached the test stops. The power
indicator goes on solid and the final results display.
Press Return/Stop to exit the test.
Interrupt Request Error
Init Rise Error
RAM Data FF Error
RAM Data 00 Error
DMA Count Error
DMA Interrupt Error
DMA Background Error
False Init Rise Error
Autofeed Falling Interrupt Error
Diagnostic Aids
3-11