4.2.5.4 Removing the ASF Assembly
1. Remove the housing. (Refer to Section 4.2.1.)
2. Release the fixed hook from the inside of the printer mechanism and
carefully but forcefully remove Gear 34 from the roller shaft in the ASF
assembly.
3. Remove the cables from the cable hook on the printer mechanism and the
hook on the ASF assembly.
4. Remove two screws (one CBS Sems R2 3x6 with plain washer and one CR
shaft installation screw).
5. With one hand move the paper depressor to the left and up, and with the
other hand remove the ASF assembly, releasing the protrusion on the left
side of the ASF assembly from the hole in the frame.
When installing the ASF assembly, make sure that the
frame and ASF assembly are attached each other without
any space between them.
Screws for ASF assembly should be used at the following
positions. (Viewing from the back of the printer)
- Right: CR shaft installation screw
- Left: Screw (CBS, Sems R2; with a
plain washer)
Disassembly & Assembly
Make sure that the
protrusion in the ASF
Assembly are in these holes
on the frame when installing
the ASF assembly.
Move the paper
depressor up and
out of the way.
Figure 4-11. Removing the ASF Assembly
Disassembly Procedures
CR Shaft
Installation Screw
CBS Sems screw
with a washer
Gear 34
ASF
protrusion
Revision A