4.2.5.3 Removing the CR Motor Assembly
1. Remove the housing. (Refer to Section 4.2.1)
2. Pull out the circuit board tray as described in "Removing the Circuit Board
Tray" on page 84, and disconnect the CR motor cable from CN7.
3. Rotate Gear 73.6 to release the carriage lock mechanism, and then move
the carriage to the center.
4. Loosen the timing belt by pushing the driven pulley holder to the inside of
the side frame, and remove the timing belt from the pulley on the CR
motor.
5. Remove two screws (CBS 3x6) and remove the CR motor assembly.
When reinstalling the timing belt, make sure the driven pulley
assembly fits tightly in the angled slots in the driven pulley
holder. (Refer to Figure 4-9.)
Compression Spring 19.6
To the outside
of the frame
To the inside of
the frame
Figure 4-9. Removing the Timing Belt
Disassembly & Assembly
Driven Pulley
Assembly
Timing
Belt
Driven Pulley
Holder
Disassembly Procedures
Connector
behind
frame
Make sure that protrusions of CR frame are in the holes of
frame when installing the CR motor assembly.
Figure 4-10. Removing and Installing the CR Motor Assembly
Revision A
Two CBS 3x6
screws
97