Reset the BETA value by pressing the MICRO FEED (v)
switch while pressing the TEAR OFF switch.
Insert the exlusive
total 0.57 mm) between the printhead and platen.
Press the MICRO FEED (") switch while pressing the TEAR OFF
switch. (Do not forget how many times you press the MICRO
FEED(A) switch [X times ]. )
Move the thickness gauge to the left and right.
BETA
Reset the
value by pressing the MICRO FEED (v) switch while
pressing the TEAR OFF switch.
Press the MICRO FEED (") switch[X-1 ]times while pressing the
TEAR OFF switch to position move the printhead to the position
one step away from the where the printhead and the thickness
gauge contact.
I
Pull the thickness gauge straight to the right with the exclusive
tension gauge (# F545). (Refer to Figure 4-1 O.)
Read the tension value (The scale on the tension gauge) when
the thickness gauge begins to move.
one measured after pressing
Press the ON LINE switch.
Figure 4-11. Mechanism Adjustment Value
START
I
thickness gauge (#5 18: 0.5 + 0.07,
I
the one measured first
(previous value) or the
END
No
Press the MICRO
Press the MICRO FEED (v) switch.
M e a s u r e m e n t
4-13
'EED (A)
switch.
REV.-A