Brady Bradyprinter THT 300X-Plus II Manual page 118

Table of Contents

Advertisement

Front Panel Controls
Front Panel LCD
LCD
Description
Backfeed Sequence
BACKFEED
This parameter establishes when and how much label backfeed occurs after a
label is removed or cut in Peel-Off, Cutter, and Applicator Modes. It has no
effect in Rewind or Tear-Off Modes. This parameter setting can be superseded
by the ~JS instruction when received as part of a label format (see the ZPL II
Programming Guide).
Note • The difference between the value entered and 100% establishes how
much backfeed occurs before the next label prints. For example, a value of 40
means that 40% of the backfeed takes place after the label is removed or cut.
The remaining 60% takes place before the next label prints. A value of BEFORE
means that all backfeed takes place before the next label prints.
• Press the right or left oval to display other choices.
Default: Default (90%)
Selections: Default, after, before, 10%, 20%, 30%, 40%, 50%,
60%, 70%, 80%, off
Adjusting Label Top Position
LABEL TOP
The label top position adjusts the print position vertically on the label. Positive
numbers adjust the label top position further down the label (away from the
printhead), negative numbers adjust the position up the label (toward the
printhead).
The displayed value represents dots.
• To increase the value, press the right oval.
• To decrease the value, press the left oval.
Default: +0
Range: –120 to +120 dot rows
90
Bradyprinter THT X-Plus II Series User Guide