Tip/Ring Device Problems - Avaya PARTNER Advanced Communications System Quick Reference Manual

Hide thumbs Also See for PARTNER Advanced Communications System:
Table of Contents

Advertisement

Quick Reference Guide

Tip/Ring Device Problems

Tip/Ring Device Problems
Problem...
Tip/ring device does not
answer
Tip/ring device does not
dial out properly
Call records wrap on
SMDR printout
Check this...
Device does not recognize the distinctive ringing
pattern used by the system. Set Distinctive Ring
(#308) for that extension to Not Active.
Device does not recognize the intercom dial tone
generated by the system. Change the setting for
Intercom Dial Tone (#309) for that extension to
Machine.
SMDR Talk Time (#611) is set to Active and SMDR
Output Format (#610) is set to 24 digits; the length of
the fields is greater than the 80 characters supported
by the printer.
Reduce the font size, or increase the characters-
per-inch setting for the printer.