Numbering the System
Planning Form Instructions
Use the floor plan and Equipment List (if available) to verify that you have
located any video stations and all remaining MLX telephones and adjuncts
connected to them.
1. On Form 2a, mark the extension jack assignments for the video stations
and the remaining MLX telephones:
a. In the Jack Type column, make sure D is checked next to the logical
ID for each digital extension jack.
b. In the Person, Location, or Function column, identify each video
station or MLX telephone by the user's name, location, or function.
2. Using the information from Form 2a, mark the digital extension adjuncts
and video stations on Form 2b, System Numbering: Digital Adjuncts:
a. Do one of the following:
b. If an adjunct is connected to the MLX telephone, enter the type of
adjunct (such as
Adjuncts column.
c. If a digital data or video station will be connected to the jack, and the
equipment supports 2B Data (such as a videoconferencing system
using a BRI interface or a v.35 interface and an ISDN terminal adapter
that supports 2B Data), check the box in the 2B column.
NOTE:
Do not connect equipment that does not support 2B Data (such as G4
FAX, or a videoconferencing system using a v.35 interface and an
ISDN terminal adapter that does not support 2B Data) to an MLX jack
configured as a 2B Data port.
d. If an MLX telephone will be connected to a desktop video system in a
passive bus configuration, check the box in the Pass. Bus column.
Also make an entry on Form 4d, MLX Telephone, to indicate that the
MLX telephone is in a passive bus configuration and note the type of
endpoint to which the MLX telephone is connected.
e. If a digital data or video system is connected to the jack, enter the
extension number in the MLX Telephone Ext. No. column.
3. In the last column, identify the type of equipment connected to the jack or
the ISDN terminal adapter connected to the jack. Also, record the
person, location, or function if desired.
Proceed to the next section, "Jacks for Analog Multiline Telephones."
If the jack does not have an adjunct connected, write
Adjuncts column and skip to Step 3.
If an adjunct is connected to the MLX telephone, proceed to
Step b.
MFM-SAA
,
MFM-T/R
,
ER1000, or 7500B
Control Unit Configuration
None
in the
) in the