MEASure:VOLTage:LOW?
FETCh:VOLTage:LOW?
Agilent 66312A, 66332A Only
These queries return the Low level voltage of a voltage pulse waveform. The instrument first measures
the minimum and maximum data points of the pulse waveform. It then generates a histogram of the pulse
waveform using 1024 bins between the maximum and minimum data points. The bin containing the most
data points below the 50% point is the low bin. The average of all the data points in the low bin is returned
as the Low level. If no low bin contains more than 1.25% of the total number of acquired points, then the
minimum value is returned by these queries.
Query Syntax
Parameters
Examples
Returned Parameters
Related Commands
MEASure:VOLTage:MAXimum?
FETCh:VOLTage:MAXimum?
Agilent 66312A, 66332A Only
These queries return the maximum output voltage reading from the measurement sample.
Query Syntax
Parameters
Examples
Returned Parameters
Related Commands
MEASure:VOLTage:MINimum?
FETCh:VOLTage:MINimum?
Agilent 66312A, 66332A Only
These queries return the minimum output voltage reading from the measurement sample.
Query Syntax
Parameters
Examples
Returned Parameters
Related Commands
MEASure[SCALar]:VOLTage:LOW?
FETCh[:SCALar]:VOLTage:LOW?
None
MEAS:VOLT:LOW?
<NR3>
MEAS:VOLT:HIGH?
CALC:REF:LOW
MEASure[:SCALar]:VOLTage:MAXimum?
FETCh[:SCALar]:VOLTage:MAXimum?
None
MEAS:VOLT:MAX?
<NR3>
MEAS:VOLT:MIN?
MEASure[:SCALar]:VOLTage:MINimum?
FETCh[:SCALar]:VOLTage:MINimum?
None
MEAS:VOLT:MIN?
<NR3>
MEAS:VOLT:MAX?
FETC:VOLT:LOW?
FETC:VOLT:MAX?
FETC:VOLT:MIN?
Language Dictionary - 4
51