Output Commands
Output commands consist of output and source commands.
Output commands control the output and digital port functions. They also control the output relay on
units with Relay Option 760.
Source commands program the actual voltage, current, and digital port output.
OUTPut
This command enables or disables the dc source output. The state of a disabled output is a condition of
zero output voltage and a model-dependent minimum source current (see *RST). Unless the NORelay
command is programmed, the OUTput command also controls the output relay on Agilent models
66332A, 6631B, 6632B, 6633B, and 6634B with Relay Option 760. If the NORelay command is sent, the
output relay state does NOT change.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
OUTPut:DFI
This command enables or disables the discrete fault indicator (DFI) outputfrom the dc source.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
OUTPut:DFI:SOURce
This command selects the source for discrete fault indicator (DFI) events.The choices are:
selects the Questionable event summary bit (bit 3 of the Status Byte Register)
QUEStionable
OPERation
selects the Operation Event summary bit (bit 7 of the Status Byte Register)
selects the Standard Event summary bit (bit 5 of the Status Byte Register)
ESB
RQS
selects the Request Service bit (bit 6 of the Status Byte Register)
selects no DFI source
OFF
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
OUTPut[:STATe] <bool> [,NORelay]
0 | OFF | 1 | ON
0
OUTP 1OUTPUT:STATE ON
OUTPut[:STATe]?
<NR1>0 or 1
*RST
*RCL
*SAV
OUTPut:DFI[:STATe]<bool>
0 | 1 | OFF | ON
OFF
OUTP:DFI 1
OUTP:DFI ON
OUTPut:DFI[:STATe]?
0 | 1
OUTP:DFI:SOUR
OUTP:DFI:SOUR<source>
QUES | OPER | ESB | RQS | OFF
OFF
OUTP:DFI:SOUR OPER
OUTPut:DFI:SOUR?
<CRD>
OUTP:DFI
Language Dictionary - 4
55