Simplified Programming Overview

Simplified Programming Overview
This section gives an overview of the basic techniques used to program the power
supply over the remote interface. This section is only an overview and does not give
all of the details you will need to write your own application programs. Refer to the
remainder of this chapter and also chapter 6, ''Application Programs'', for more
details and examples. Also refer to the programming reference manual that came with
your computer for details on outputting command strings and entering data.

Using the APPLy Command

The APPLy command provides the most straightforward method to program the
power supply over the remote interface. For example, the following statement
executed from your computer will set the power supply to an output of 3 V rated at 1 A:
''APPL 3.0, 1.0''

Using the Low-Level Commands

Although the APPLy command provides the most straightforward method to program
the power supply, the low-level commands give you more flexibility to change
individual parameters. For example, the following statements executed from your
computer will set the power supply to an output of 3 V rated at 1 A:
''VOLT 3.0''
''CURR 1.0''
Set output voltage to 3.0 V
Set output current to 1.0 A