4 - Language Dictionary
SYSTem:LOCal
For RS-232 Operation Only
This command places the dc source in local mode during RS-232 operation. The front panel keys are
functional.
Command Syntax
Parameters
Example
Related Commands
SYSTem:REMote
For RS-232 Operation Only
This command places the dc source in remote mode during RS-232 operation. This disables all front
panel keys except the Local key. Pressing the Local key while in the remote state returns the front panel to
the local state.
Command Syntax
Parameters
Example
Related Commands
SYSTem:RWLock
For RS-232 Operation Only
This command places the dc source in remote mode during RS-232 operation. All front panel keys
including the Local key are disabled. Use SYSTem:LOCal to return the front panel to the local state.
Command Syntax
Parameters
Example
Related Commands
*IDN?
This query requests the dc source to identify itself. It returns a string composed of four fields separated by
commas.
Query Syntax
Returned Parameters
Example
70
SYSTem:LOCal
None
SYST:LOC
SYST:REM
SYST:RWL
SYSTem:REMote
None
SYST:REM
SYST:LOC
SYST:RWL
SYSTem:RWLock
None
SYST:RWL
SYST:REM
SYST:LOC
*IDN?
<AARD>
Field
Agilent Technologies
xxxxxA
nnnnA-nnnnn
<A>.xx.xx
AGILENT,66312A,0,A.00.01
Information
Manufacturer
model number followed by a letter suffix
10-character serial number or 0
Revision levels of firmware.