OUTPut:RELay

Agilent 66332A, 6632B, 6633B, 6634B, 6611C, 6612C, 6613C, 6614C Only
This command is only valid for units with Relay Option 760, otherwise an error will occur. Programming
ON closes the output relay contacts; programming OFF opens them. The relay is controlled independently
of the output state. If the dc source is supplying power to a load, that power will appear at the relay
contacts during switching.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands

OUTPut:RELay:POLarity

Agilent 66332A, 6632B, 6633B, 6634B, 6611C, 6612C, 6613C, 6614C Only
This command is only valid for units with Relay Option 760, otherwise an error will occur. Programming
NORMal causes the output relay polarity to be the same as the dc source output. Programming REVerse
causes the relay output polarity to be opposite to that of the dc source output. If OUTPut = ON when either
command is sent, the output voltage is set to 0 during the time that the relays are changing polarity.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands

OUTPut:RI:MODE

This command selects the mode of operation of the Remote Inhibit protection. The RI mode is stored in
non-volatile memory. The following modes can be selected:
causes a TTL low signal on the INH input to disable the output. The only way
LATChing
to clear the latch is by sending an OUTPut:PROTection:CLEAR command
while the INH input is false.
allows the INH input to disable the output in a non-latching manner. In other
LIVE
words, the output follows the state of the INH input. When INH is low true, the
output is disabled. When INH is high the output is not affected.
the INH input is disabled.
OFF
Command Syntax
Parameters
Examples
Query Syntax
Returned Parameters
Related Commands
OUTPut:RELay[:STATe]<bool>
0 | 1 | OFF ON
0
OUTP:REL 1OUTP:REL OFF
OUTPput:RELay?
0 | 1
OUTP *RCL *SAV
OUTPut:RELay:POLarity<CRD>
NORMal | REVerse
NORM
OUTP:REL:POL NORM
OUTPput:RELay:POLarity?
NORM | REV
OUTP *RCL *SAV
OUTPut:RI:MODE <mode>
LATChing | LIVE | OFF
OUTP:RI:MODE LIVE
OUTPut:RI:MODE?
<CRD>
OUTP:PROT:CLE