SENSe:FUNCtion

Agilent 66312A, 66332A Only
This command configures the measurement sensor to measure either voltage or current when an acquire
trigger is used. The query returns the function setting, either VOLT or CURR.
Command Syntax
Parameters
Examples
Query Syntax
Returned Parameters

SENSe:SWEep:OFFSet:POINts

Agilent 66312A, 66332A Only
This command defines the offset in a data sweep when an acquire trigger is used. Negative values
represent data samples taken prior to the trigger.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands

SENSe:SWEep:POINts

This command defines the number of points in a data sweep.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands

SENSe:SWEep:TINTerval

This command defines the time period between samples
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
SENSe:FUNCtion <function
"VOLTage" | "CURRent"
SENS:FUNC "VOLT"
SENSe:FUNCtion?
<SRD>
SENSe:SWEep:OFFSet:POINts <NRf+>
-4095 through 2,000,000,000
0
SENS:SWE:OFFS:POIN -2047
SENSe:SWEep:OFFSet:POINts?
<NR3>
SENS:SWE:TINT
SENS:SWE:POIN
SENSe:SWEep:POINts<NRf+>
0 through 4096
2048
SENS:SWE:POIN 1024
SENSe:SWEep:POINts?
<NR3>
SENS:SWE:TINT
SENS:SWE:OFFS
SENSe:SWEep:TINTerval<NRf+>
15.6 microseconds through 31200 seconds
15.6 microseconds
SENS:SWE:TINT 31.2E-6
SENSe:SWEep:TINTerval?
<NR3>
SENS:SWE:POIN
SENS:SWE:OFFS
Language Dictionary - 4
MEAS:ARR
MEAS:ARR
MEAS:ARR