[Source:]Voltage:alc:bandwidth? [Source:]Voltage:alc:bwidth; [Source:]Voltage:trigger; [Source:]Voltage:protection - Agilent Technologies 66312A Programming Manual

Dynamic measurement dc source; system dc power supply
Hide thumbs Also See for 66312A:
Table of Contents

Advertisement

4 - Language Dictionary
[SOURce:]VOLTage:ALC:BANDwidth?
[SOURce:]VOLTage:ALC:BWIDth?
Agilent 66332A, 6631B, 6632B, 6633B and 6634B Only
These queries return the setting of the output mode switch. The output mode switch is used to connect or
disconnect the the output capacitor located inside the unit. The returned value is 15,000 if the switch is set
to Normal and 60,000 if the switch is set to Fast.
Query Syntax
Examples
Returned Parameters

[SOURce:]VOLTage:TRIGger

This command sets the pending triggered voltage level of the dc source. The pending triggered level is a
stored voltage value that is transferred to the output terminals when a trigger occurs. In order for a trigger
to occur, the trigger subsystem must be initiated (see the INITiate command in the trigger subsystem).
Command Syntax
Parameters
Default Suffix
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands

[SOURce:]VOLTage:PROTection

This command sets the overvoltage protection (OVP) level of the dc source. If the output voltage exceeds
the OVP level, then the dc source output is disabled and the Questionable Condition status register OV bit
is set (see chapter 3 under Programming the Status Registers). An overvoltage condition can be cleared
with the OUTP:PROT:CLE command after the condition that caused the OVP trip is removed. The OVP
always trips with zero delay and is unaffected by the OUTP:PROT:DEL command.
Command Syntax
Parameters
Default Suffix
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands
60
[SOURce]:VOLTage:ALC:BANDwidth?
[SOURce]:VOLTage:ALC:BWIDth?
VOLT:ALC:BAND?
<NR3>
[SOURce][:VOLTage[:LEVel]:TRIGgered[:AMPLitude]<NRf+>
see Table 4-3
V (volts)
0
VOLT:TRIG 20
[SOURce]:VOLTage[LEVel]:TRIGgered[:AMPLitude]?
<NR3>
VOLT
*RST
[SOURce]:VOLTage:PROTection[:LEVel]<NRf+>
see Table 4-3
V (volts)
MAX
VOLT:PROT 21.5
[SOURce]:VOLTage:PROTection[:LEVel]?
<NR3>
OUTP:PROT:CLE
OUTP:PROT:DEL
VOLTAGE:ALC:BWIDth?
VOLTAGE:LEVEL:TRIGGERED 20
VOLT:PROT:LEV MAX

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6631b6632b66332a6633b6634b6611c ... Show all

Table of Contents