set cli-parameters

Description Sets options that control CLI behavior. If you are accessing the CLI through the network port, settings
apply to the current CLI session only. If you are accessing the CLI through the enclosure's CLI port,
settings persist across sessions.
The base, locale, precision, temperature scale, timeout, and units settings are read from the user's
profile, and can be overridden by using this command.
Syntax
set cli-parameters
[base 2|10]
[console|api|api-embed]
[brief enabled|disabled|on|off]
[locale English|en|Spanish|es|French|fr|German|de|Italian|it|Japanese|ja
|Korean|ko|Dutch|nl|Chinese-simplified|zh-s|Chinese-traditional|zh-t]
[pager enabled|disabled|on|off]
[precision #]
[storage-size-base 2|10]
[storage-size-precision #]
[storage-size-units auto|MB|GB|TB]
[temperature-scale celsius|c|fahrenheit|f]
[timeout #]
[units auto|MB|GB|TB]
Parameters base 2|10
Optional. Sets the base for entry and display of storage-space sizes:
2: Sizes are shown as powers of 2, using 1024 as a divisor for each magnitude.
10: Sizes are shown as powers of 10, using 1000 as a divisor for each magnitude.
Operating systems usually show volume size in base 2. Disk drives usually show size in base 10.
Memory (RAM and ROM) size is always shown in base 2.
console|api|api-embed
Optional. Sets the output format:
console: Supports interactive use of the CLI by displaying command output in easily readable
format. This format automatically sizes fields according to content, adjusts content to window
resizes, and displays some information in localized form. This is the default.
api: Supports scripting by displaying command output in XML. All objects are displayed at the
same level, related by COMP elements.
api-embed: Alternate form of XML output which displays "child" objects embedded (indented)
under "parent" objects.
ipa: Alternate form of XML output for internal use only.
json: Alternate data-interchange format for internal use only.
brief enabled|disabled|on|off
Optional. When enabled, shows only the name, key, and type attributes of objects in XML API
format. Disabled by default.
locale
English|en|Spanish|es|French|fr|German|de|Italian|it|Japanese|ja|Korean
|ko|Dutch|nl|Chinese-simplified|zh-s|Chinese-traditional|zh-t
Optional. The display language.
pager enabled|on|disabled|off
Optional. Specifies whether to halt output after each full screen to wait for keyboard input. Enabled
by default. When using XML API format, which is intended for scripting, disable paging.
precision #
Optional. Sets the number of decimal places (1–10) for display of storage-space sizes.