HP P2000 Reference Manual page 308

Msa system
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

Table 18
controllers properties (continued)
Name
failed-over-
numeric
fail-over-
reason
fail-over-
reason-numeric
sc-fw
vendor
model
sc-cpu-type
sc-cpu-speed
internal-
serial-number
cache-lock
cache-lock-
numeric
write-policy
write-policy-
numeric
description
part-number
revision
dash-level
fru-shortname
mfg-date
mfg-date-
numeric
308 XML API basetype properties
Type
Description
Numeric equivalents for failed-over values.
string
0: No
1: Yes
If failed-over is No, Not applicable appears; otherwise, one of the
string
reasons in the next row appears.
Numeric equivalents for fail-over-reason values.
string
Storage Controller firmware version.
string
Controller manufacturer.
string
Controller model.
string
Storage Controller processor type.
string
Storage Controller processor speed.
sint32
Internal serial number of the controller.
string
Shows whether hosts are prevented from using the SCSI MODE SELECT
string
command to change the storage system's write-back cache setting.
No: Hosts are permitted to disable write-back cache.
Yes: Hosts are prevented from disabling write-back cache. This is the
default.
Numeric equivalents for cache-lock values.
string
0: No
1: Yes
The current, system-wide cache policy as determined by auto-write-through
string
(AWT) logic. This value is not settable by users. If an AWT trigger condition
(such as a CompactFlash failure) is met, the cache policy for all volumes
changes to write-through, overriding the volume-specific settings. When the
problem is corrected, the cache policy reverts to the value configured for each
individual volume.
write-back: This is the normal state.
write-through
Not up: The controller is not up.
Numeric equivalents for write-policy values.
string
0: write-back
1: write-through
2: Not up.
FRU long description.
string
OEM part number for the FRU.
string
OEM hardware-revision level for the FRU.
string
FRU template revision number.
string
FRU short description.
string
Date and time, in the format year-month-day hour:minutes:seconds
string
(UTC), when the controller's PCBA was programmed.
Unformatted mfg-date value.
string