Table 18
controllers properties (continued)
Name
Type
mfg-location
string
mfg-vendor-id
string
health
string
health-numeric
string
health-reason
string
health-blame
string
health-blame-
string
numeric
position
string
position-
string
numeric
phy-isolation
string
phy-isolation-
string
numeric
Example
# show controllers
...
<OBJECT basetype="controllers" name="controllers" oid="1" format="pairs">
<PROPERTY name="durable-id" type="string">controller_a</PROPERTY>
<PROPERTY name="controller-id" type="string">A</PROPERTY>
<PROPERTY name="controller-id-numeric" type="string">1</PROPERTY>
<PROPERTY name="serial-number" type="string">SN</PROPERTY>
Description
City, state/province, and country where the FRU was manufactured.
JEDEC ID of the FRU manufacturer.
•
OK
•
Degraded
•
Fault
•
Unknown
•
N/A
Numeric equivalents for health values.
•
0: OK
•
1: Degraded
•
2: Fault
•
3: Unknown
•
4: N/A
More information about the health value.
If health is not OK, this indicates whether this component or one of its
subcomponents is to blame.
•
none: This component and its subcomponents are ok.
•
self: This component has a problem.
•
child: A subcomponent has a problem.
•
both: Both this component and at least one subcomponent have a problem.
Numeric equivalents for health-blame values.
•
0: none
•
1: self
•
2: child
•
3: both
Position of the controller in the enclosure.
•
Top: The controller is in the top slot.
•
Bottom: The controller is in the bottom slot.
Numeric equivalents for position values.
•
0: Top
•
1: Bottom
Shows whether the automatic disabling of SAS expander PHYs having high error
counts is enabled or disabled for this controller.
•
Enabled: PHY fault isolation is enabled. This is the default.
•
Disabled: PHY fault isolation is disabled.
Numeric equivalents for phy-isolation values.
•
0: Enabled
•
1: Disabled
HP P2000 G3 MSA System CLI Reference Guide 309