Download Print this page
HP P2000 Replacement Instructions

HP P2000 Replacement Instructions

Hp storageworks p2000 g3 modular smart array controller module replacement instructions (590365-002, june 2010)
Hide thumbs Also See for P2000:

Advertisement

HP StorageWorks
P2000 G3 Modular Smart Array
Controller Module Replacement
Instructions
This document details procedures for replacing a failed
controller module in an HP StorageWorks P2000 G3
MSA system.
© Copyright 2009, 2010 Hewlett-Packard Development Company,
L.P.
Second edition: March 2010
The information in this document is subject to change without notice.
Printed in the US.
www.hp.com
*590365-002*

About this document

Illustrations in this document show generic representations of modules
and enclosures; procedures are the same for all modules shipped
with this document.
The Storage Management Utility (SMU) and the Command Line Inter-
face (CLI) can be used to manage the enclosure. Tasks in this docu-
ment demonstrate using the SMU.
For the latest product documentation, see the HP website at
www.hp.com/support/manuals. Under the storage banner, navigate
to the page for your storage enclosure.

Before you begin

Observe the following:
CAUTION:
Removing a module from an operational enclosure significantly
changes air flow within the enclosure. Openings must be
populated for the enclosure to cool properly. Leave modules
in the enclosure until a replacement is available.
Parts can be damaged by electrostatic discharge; use proper
anti-static protection. Keep parts in electrostatic containers
until needed and ensure you are properly grounded when
touching static-sensitive components.
IMPORTANT:
When replacing both controllers in an operational enclosure,
do as follows:
1.
Replace one controller as detailed in these instructions.
2.
Wait 30 minutes. This pause ensures that the two controllers
and their ownership of the vdisks have enough time to fully
stabilize.
3.
Examine system status and event logs to ensure that the system
is stable.
4.
Replace the other controller as detailed in these instructions.
IMPORTANT:
When two controllers are installed in an enclosure, they must
be the same model. Mixing controller types in the same
enclosure is not supported.
NOTE:
To reduce impact on system performance, perform all
maintenance tasks during periods of low system activity or
during a system maintenance window.
Page 1
http://

Advertisement

loading

Summary of Contents for HP P2000

  • Page 1: About This Document

    Before you begin Observe the following: This document details procedures for replacing a failed controller module in an HP StorageWorks P2000 G3 CAUTION: MSA system. Removing a module from an operational enclosure significantly changes air flow within the enclosure.
  • Page 2: Verifying Module Failure

    The following illustration shows controller module locations: For information about all hosts (IDs and names): In the Configuration View panel, select Hosts and then click View > Overview. For information about a specific host (IDs, names, and mappings): In the Configuration View panel, expand the display under Hosts and then select a specific host.
  • Page 3: Transporting Compactflash

    Turn the thumbscrews until the screws disengage from the module Carefully remove the CompactFlash from the new controller and set (1) and rotate both latches downward to disengage the module it aside. from the internal connector (2). Insert the CompactFlash that you removed from the failed controller Pull the module straight out of the enclosure (3).
  • Page 4: Additional Information

    Reconnect the cables. Additional information NOTE: HP P2000/MSA Disk Systems: http://www.hp.com/go/msa After installing a controller in an operational, dual-controller system, the new controller automatically HP storage: http://www.hp.com/storage begins to initialize. If the firmware versions differ HP support: http://www.hp.com/support between the two controllers, Partner Firmware Upgrade...

This manual is also suitable for:

P2000 g3