Redundancy - HP P2000 Reference Manual

Msa system
Hide thumbs Also See for P2000:
Table of Contents

Advertisement

redundancy

Properties
Table 49
redundancy properties
Name
redundancy-mode
redundancy-
mode-numeric
redundancy-
status
redundancy-
status-numeric
controller-a-
status
controller-a-
status-numeric
controller-a-
serial-number
controller-b-
status
controller-b-
status-numeric
controller-b-
serial-number
Example
# show redundancy-mode
...
<OBJECT basetype="redundancy" name="system-redundancy" oid="1" format="pairs">
<PROPERTY name="redundancy-mode" type="string">Active-Active ULP</PROPERTY>
<PROPERTY name="redundancy-mode-numeric" type="string">8</PROPERTY>
<PROPERTY name="redundancy-status" type="string">Redundant</PROPERTY>
<PROPERTY name="redundancy-status-numeric" type="string">8</PROPERTY>
<PROPERTY name="controller-a-status" type="string">Operational</PROPERTY>
<PROPERTY name="controller-a-status-numeric" type="string">0</PROPERTY>
<PROPERTY name="controller-a-serial-number" type="string">SN</PROPERTY>
366 XML API basetype properties
Type
Description
Active-Active ULP: Both controllers are active using ULP (Unified LUN
string
Presentation). Data for volumes configured to use write-back cache is
automatically mirrored between the two controllers to provide fault tolerance.
Single Controller: The enclosure contains a single controller.
Numeric equivalents for redundancy-mode values.
string
8: Active-Active ULP
9: Single Controller
Redundant: Both controllers are operational.
string
Operational but not redundant: In active-active mode, one
controller is operational and the other is offline. In single-controller mode,
the controller is operational.
Unknown: Status information is not available.
Numeric equivalents for redundancy-status values.
string
8: Redundant
9: Operational but not redundant
10: Unknown
Operational: The controller is operational.
string
Down: The controller is installed but not operational.
Not Installed: The controller is not installed.
Numeric equivalents for controller-a-status values.
string
0: Operational
1: Down
2: Not Installed
Controller module serial number
string
Not Available: The controller is down or not installed.
Operational: The controller is operational.
string
Down: The controller is installed but not operational.
Not Installed: The controller is not installed.
Numeric equivalents for controller-b-status values.
string
0: Operational
1: Down
2: Not Installed
Controller module serial number
string
Not Available: The controller is down or not installed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

P2000 g3

Table of Contents