• MSA70 disk enclosures are supported for use with P2000 G3 arrays, but must have firmware 2.18 installed. Please check the MSA70 or P2000 G3 QuickSpecs to confirm which version MSA70 firmware is supported. Known issues and workarounds Issue: In Japanese locale, the user cannot log in to the Storage Management Utility (SMU) if a HP StorageWorks D2700 Disk Enclosure is attached to the MSA System.
Page 5
Update 5 to access the array. Workaround: See issue 583218 on the Red Hat Bugzilla bug-tracking system https://bugzilla.redhat.com/ show_bug.cgi?id=583218 for the current status of the issue and possible workarounds. HP StorageWorks P2000 G3 iSCSI MSA System Controller Firmware Release Notes...
Page 6
Issue: Using a long IQN name for iSCSI initiators may lead to issues while using SCSI-3 reservations and Persistent Group Reservations, particularly when trying to create large clusters with multiple paths to each LUN. A predefined area is used to store SCSI-3 reservation keys for each initiator path to each LUN and, when a large number of IQN entries are attempted to be stored, the array can run out of space in this area.
Page 7
LUN and the mapped to a LUN and the mapped to a LUN and the Maximum IQN character Maximum IQN character Maximum IQN character length length length 1–17 HP StorageWorks P2000 G3 iSCSI MSA System Controller Firmware Release Notes...
Page 8
Issue: A P2000 G3 iSCSI MSA System LUN which has been newly added to a Citrix XenServer 5.6 pool may not return to an active Storage Repository (SR) state following removal or replacement of an array controller.
Number of Reads and Number of Writes over time to determine IOPs, and the change in Data Read and Data Written over time to determine Bytes per second. Effective date November 2010 HP StorageWorks P2000 G3 iSCSI MSA System Controller Firmware Release Notes...