6. Explanation of sensor amplifier

r
t Detection output action
indicator lamp (orange color)
q Jog switch
Change values by pushing down to (+) or (-) side.
w Mode selection switch
[RUN]: Set to this position in the normal detective condition.
[SET]:
Set to this position for setting the sense degree.
e LED display
The current reflection light amount is displayed with numbers from 0 to 4090 when the mode selection switch is set to [RUN]. The
current threshold value (limit value to decide ON/OFF of the sensor) is displayed with numbers from 0 to 4090 when the mode
selection switch is set to [SET].
r Selection of detection output
Which one of detection output 1 or 2 is selected is indicated. Rotation of the jog switch can change 1 to 2 and vise versa. For this
equipment, output 1 is used.
t Detection output action indicator lamp
LED is turned on when the sensor is ON. For this equipment, the indicator 1 shows the sensor condition.
Selection of detection
output indicator lamp
OUT
OUT
e 4 digit LED display
(with back light)
PUSH
PUSH
1
1
1
1
2
2
2
2
SET
SET
RUN
RUN
BAS-6150
Chapter 5 Adjustment
q Jog switch
MODE
MODE
w Mode selection switch
1498S