Chapter 5 Adjustment
7-2-3. Adjustment of the lens position at replacement of gauges
The lens needs alignment of its position with the width of gauge for replacement of gauges. Proceed to following
steps for lens position adjustment.
Carrige feed (L)
Flap clamp (L)
1. Turn on the power and press down the foot start switch.
The home position is detected, moving the carriage feed forward. Then the carriage feed moves to the waiting position.
2. Set the body.
3. Press down the foot forward switch once.
The flap clamp opens when the carriage feed moves to the cloth set position.
4. Keep pressing down the foot forward switch until both flap clamps go down.
5. Press the emergency stop switch.
The error code (E-500) appears on the panel and the buzzer sounds.
(Note) Be sure to adjust the machine after the emergency stop switch is pressed. Otherwise, an accidental
press on the foot switch causes the binder and carriage feed to move and may cause injury.
6. Reset the emergency stop switch.
The buzzer stops.
When the emergency stop switch is reset, the feeding motor becomes free and the carriage feed can be moved manually.
7. Move the carriage feed manually so that the end of the folding plate gets to the red spot
position of the reflected light from the lens.
8. Pinch the sensor holder R•L with fingers and slide it to set the light spot on the reflection
seal on the folding plate for adjustment of right and left flap detection sensors.
Also adjust the value of the sensor amplifier to be the maximum.
If required, loosen the bolt and adjust the direction of rotation.
64
Binder
Flap clamp (R)
Carrige feed (R)
1504S
Foot start switch
Foot forward switch
1500S
BAS-6150
Bolt
1505S