Foot Switch Timer Setting - Brother BAS-6150 Instruction Manual

Automatic lockstitch pocket welt sewer
Hide thumbs Also See for BAS-6150:
Table of Contents

Advertisement

3. Foot switch timer setting

If the forward switch q is continued to be pressed at sewing, the clamp can be continued to
operate in a specified interval.
1. In environment parameter setting, the contents of the parameter for the foot switch timer
setting (No. 22) is changed to the ON display.
2. With that condition , press the forward switch q and the mode is changed to the setting
mode.
The "ENTER" key e is not pressed.
3. Press the forward switch q to move the clamp in the specified order. The interval of each
operation is memorized. Pressing the backward switch w returns one step of operation.
4. Press forward switch q to descend all clamps.
5. Contents of the parameter of [No.21 Foot switch operation] is set to ON display.
6. Press the "ENTER" key e and the environment parameter setting is ended.
q
w
1529S
BAS-6150
Chapter 7 Environment setting
e
1457S
87