Troubleshooting The Ethernet Controller; Network Connection Problems - IBM 8480 - Eserver xSeries 205 Maintenance And Troubleshooting Manual

Hardware maintenance manual
Hide thumbs Also See for 8480 - Eserver xSeries 205:
Table of Contents

Advertisement

Troubleshooting the Ethernet controller

This section provides troubleshooting information for problems that might occur with
the 10/100/1000 Mbps Ethernet controller.

Network connection problems

If the Ethernet controller cannot connect to the network, check the following
conditions:
v Make sure that the cable is installed correctly.
v Determine whether the hub supports auto-negotiation. If it does not, try
v Check the Ethernet controller LEDs on the operator information panel and on the
v Make sure that you are using the correct device drivers which are supplied with
v Check for operating-system-specific causes for the problem.
v Make sure that the device drivers on the client and server are using the same
v Test the Ethernet controller.
30
IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
The network cable must be securely attached at all connections. If the cable is
attached but the problem remains, try a different cable.
If you set the Ethernet controller to operate at either 100 Mbps or 1000 Mbps,
you must use Category 5 or higher cabling.
configuring the integrated Ethernet controller manually to match the speed and
duplex mode of the hub.
rear of the server.
These LEDs indicate whether a problem exists with the connector, cable, or hub.
– The Ethernet transmit/receive activity LED, on the operator information panel,
is lit when the Ethernet controller sends or receives data over the Ethernet
Network. If the Ethernet transmit/receive activity LED is off, make sure that
the hub and network are operating and that the correct device drivers are
installed.
– The Ethernet link status LED, on the rear of the server, is lit when the
Ethernet controller receives a LINK pulse from the hub. If the LED is off, there
might be a defective connector or cable or a problem with the hub.
your server.
protocol.
The way the Ethernet controller is tested depends on which operating system
you are using (see the Ethernet controller device driver README files).

Advertisement