Temperature Error Messages; Fan Error Messages - IBM 8480 - Eserver xSeries 205 Maintenance And Troubleshooting Manual

Hardware maintenance manual
Hide thumbs Also See for 8480 - Eserver xSeries 205:
Table of Contents

Advertisement

Temperature error messages

Note: See "System" on page 112 to determine which components should be replaced by a field service technician.
Message
DASD Over Temperature
(level-critical; direct access storage device
bay x was over temperature)
DASD Over recommended Temperature
(sensor x)
(level-warning; DASD bay x had over
temperature condition)
DASD under recommended temperature
(sensor x) (level-warning; direct access
storage device bay x had under
temperature condition)
DASD Over Temperature
(level-critical; sensor for DASD1 reported
temperature over recommended range)
Power supply x Temperature Fault
(level-critical; power supply x had over
temperature condition)
System board is over recommended
temperature
(level-warning; system board is over
recommended temperature)
System board is under recommended
temperature
(level-warning; system board is under
recommended temperature)
System over temperature for CPU x
(level-warning; CPU x reporting over
temperature condition)
System under recommended CPU x
temperature (level - warning; system
reporting under temperature condition for
CPU x)

Fan error messages

Note: See "System" on page 112 to determine which components should be replaced by a field service technician.
Message
Fan x failure (level-critical; fan x had a
failure)
Fan x fault (level-critical; fan x beyond
recommended RPM range)
Fan x outside recommended speed
action
104
IBM xSeries 205 Type 8480: Hardware Maintenance Manual and Troubleshooting Guide
Action
v Ensure that the system is being properly cooled; see "System
reliability considerations" on page 37.
v Ensure that the system is being properly cooled; see "System
reliability considerations" on page 37.
v Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 3.
v Ensure system is being properly cooled; see "System reliability
considerations" on page 37.
1. Ensure system is being properly cooled; see "System reliability
considerations" on page 37.
2. Replace power supply x
1. Ensure system is being properly cooled; see "System reliability
considerations" on page 37.
2. Replace the system board.
v Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 3.
v Ensure system is being properly cooled; see "System reliability
considerations" on page 37.
v Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 3.
Action
1. Check connections to fan x.
2. Replace fan x.
1. Check connections to fan x.
2. Replace fan x.
1. Replace fan x.

Advertisement